Wells WVAE-55FS Instruções de Operação Página 12

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 29
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 11
Operation and Care Manual #8452/53/55
PG.11
The filters are the only owner-serviceable components of the ventilator hood system. For any other problem which
cannot be remedied by servicing the filters, contact an authorized fryer or ventilator service agency. Contact an
authorized Ansul
® distributor for service of the fire suppression system.
TROUBLESHOOTING
SERVICE PARTS LIST
IMPORTANT: Use only factory authorized service parts
and replacement filters. Contact the
Alto-Shaam service department for
specific information.
NORMAL MAINTENANCE ITEMS
Odor Control Charcoal Filter
Grease Vapor HEPA Filter
Stainless Steel Baffle Filter
Leg Assembly
IMPORTANT: Parts used for the Ansul
®
fire suppression
system are not serviceable by the
owner/operator. Procedures for servicing
fire suppression equipment are described
in the Ansul
®
R-102 System Design,
Installation, Recharge and Maintenance
Manual (#418087). This manual is
intended for use by authorized service
personnel only.
HAVE THE FOLLOWING INFORMATION AVAILABLE
WHEN CALLING FOR SERVICE
CUSTOMER SERVICE DATA
PURCHASED FROM:______________________________________
DATE INSTALLED:_______________________________________
INSTALLATION TECHNICIAN:________________________________
EQUIPMENT MODEL NUMBER:______________________________
EQUIPMENT SERIAL NUMBER: ______________________________
Voltage: 208V 240V 308-415V
AUTHORIZED SERVICE AGENCY: ____________________________
ADDRESS:____________________________________
_____________________________________
PHONE:______________________________________
PROBLEM REMEDY
Unit will not operate. Circuit breaker is tripped. Reset breaker. If tripping persists,
contact a licensed electrician for repair of field wiring or contact
an authorized service agency for repairs.
A buzzer sounds continuously and unit Ansul
®
system has tripped. Contact an
will not operate. authorized Ansul
®
agent for service and repairs.
Check Filters light is illuminated. Grease Vapor HEPA filter missing or not in the proper position.
Make certain both the HEPA filter and Stainless Steel Baffle filter
are properly installed in their respective rails.
Replace Filters light is illuminated. Grease Vapor HEPA filter or charcoal filter nearing the end of
their service life. Be sure to have proper replacement filters on
hand. Always replace the HEPA filter and charcoal filter at the
same time.
Service Required light is illuminated. Grease Vapor HEPA filter or charcoal filter is plugged.
Replace filters.
Fire damper on exhaust color has closed. Contact authorized
service agency for repairs.
One or more vacuum sensing lines are plugged. Contact an
authorized service agency for repairs.
NOTE: After 10 seconds, if there is not sufficient air flow for proper operation, the service required light will
turn ON and the fryer will be de-energized. The power switch must be turned OFF to reset the system
before the fryer can be operated.